Characteristic
● Tg150℃(DSC)● UV Blocking/AOI compatible
● Good PCB mechanical processability
Application Area
● Computer, instrumentation, VCR, communication equipment, game station, automotive, and etc.● Not suitable for Anit-CAF application
● Not suitable fro >2 oz heavy copper, HDI and >/=12L high layer count application
- Product Performance
- Product Certificate
- Data Download
Items | Method | Condition | Unit | Typical Value | |
---|---|---|---|---|---|
Tg | IPC-TM-650 2.4.25 | DSC | ℃ | 150 | |
Td | IPC-TM-650 2.4.24.6 | 5% wt. loss | ℃ | 310 | |
CTE (Z-axis) | IPC-TM-650 2.4.24 | Before Tg | ppm/℃ | 65 | |
After Tg | ppm/℃ | 300 | |||
50-260℃ | % | 4.2 | |||
T260 | IPC-TM-650 2.4.24.1 | TMA | min | 15 | |
T288 | IPC-TM-650 2.4.24.1 | TMA | min | 2 | |
Thermal Stress | IPC-TM-650 2.4.13.1 | 288℃, solder dip | -- | 60S No Delamination | |
Volume Resistivity | IPC-TM-650 2.5.17.1 | After moisture resistance | MΩ.cm | 4.7E + 08 | |
E-24/125 | MΩ.cm | 5.3E + 06 | |||
Surface Resistivity | IPC-TM-650 2.5.17.1 | After moisture resistance | MΩ | 5.3E + 07 | |
E-24/125 | MΩ | 5.4E + 06 | |||
Arc Resistance | IPC-TM-650 2.5.1 | D-48/50+D-4/23 | s | 120 | |
Dielectric Breakdown | IPC-TM-650 2.5.6 | D-48/50+D-4/23 | kV | 60 | |
Dissipation Constant (Dk) | IPC-TM-650 2.5.5.9 | 1MHz | -- | 4.6 | |
IEC 61189-2-721 | 10GHz | -- | — | ||
Dissipation Factor (Df) | IPC-TM-650 2.5.5.9 | 1MHz | -- | 0.015 | |
IEC 61189-2-721 | 10GHz | -- | — | ||
Peel Strength (1oz HTE copper foil) | IPC-TM-650 2.4.8 | A | N/mm | — | |
After thermal Stress 288℃,10s | N/mm | 1.8 | |||
125℃ | N/mm | 1.6 | |||
Flexural Strength | LW | IPC-TM-650 2.4.4 | A | MPa | 600 |
CW | IPC-TM-650 2.4.4 | A | MPa | 500 | |
Water Absorption | IPC-TM-650 2.6.2.1 | E-1/105+D-24/23 | % | 0.15 | |
CTI | IEC60112 | A | Rating | PLC 3 | |
Flammability | UL94 | C-48/23/50 | Rating | V-0 | |
E-24/125 | Rating | V-0 |
Remarks:
1. Specification sheet: IPC-4101/21, is for your reference only.
2. All the typical values are based on the 1.6mm specimen,while the Tg is for specimen≥0.50mm.
3. All the typical values listed above are for your reference only and not intended for specification. Please contact Shengyi Technology Co., Ltd. for detailed information. All rights from this data sheet are reserved by Shengyi Technology Co., Ltd.
Explanation: C=Humidity conditioning, D=Immersion conditioning in distilled water, E=Temperature conditioning
The first digit following the letter indicates the duration of preconditioning in hours, the second digit the preconditioning temperature in ℃ and the third digit the relative humidity.