Items | Method | Condition | Unit | Typical Value |
---|---|---|---|---|
Tg | 2.4.24 | TMA | ℃ | >250 |
Td | 2.4.24.6 | 5% wt. loss | ℃ | 429 |
T300 |
2.4.24.1 |
TMA |
min |
>60 |
CTE(X/Y-axis) | 2.4.24 | 50-260℃ (X/Y) | ppm/℃ | 12~15 |
CTE(Z-axis) | 2.4.24 | α1 (before Tg) | ppm/℃ | 45 |
50-260℃ | % | 1.20 | ||
Dissipation Constant (1GHz) | 2.5.5.9 | C-24/23/50 | - | 4.12 |
Dissipation Factor (1GHz) |
2.5.5.9 |
C-24/23/50 |
- | 0.007 |
Volume Resistivity | 2.5.17.1 | C-96/35/90 | MΩ/cm | 7.45 x 107 |
Surface Resistivity |
2.5.17.1 |
C-96/35/90 | MΩ | 4.79 x 107 |
Arc Resistance | 2.5.1 | D-48/50+D-0.5/23 | kV | 180 |
Electrical Strength | 2.5.6.2 | D-48/50+D-0.5/23 | kV | 85 |
Dielectric Breakdown | 2.5.6 | D-48/50+D-0.5/23 | kV | 40.5 |
Peel Strength | 2.4.8 | 288℃/10s | N/mm |
1.37 [7.82] |
Young's Modulus | 200℃ | GPa | - | 10.3 |
Flexural Strength | 2.4.4 | A | MPa |
530 [76,850]
439 [63,655] |
Water Absorption | 2.6.2.1 | D-24/23 | % | 0.26 |
Flammability |
UL94 |
C-48/23/50 |
Rating |
HB |
Remarks:
1. Specimen thickness: 1.6mm (Electrical Strength and Young's Modulus Specimen thickness 0.1mm). Test method is according to IPC-TM-650.
2. All the typical values listed above are for your reference only. Please turn to Shengyi Technology Co., Ltd. for more detailed information, and all rights from this data sheet are reserved by Shengyi Technology Co., Ltd.3. Explanation:C=Humidity conditioning, D=Immersion conditioning in distilled water, E=Temperature conditioning.
The figures following the letter symbols indicate with the first digit the duration of the preconditioning in hours, with the second digit the preconditioning temperature in ℃ and the third digit the relative humidity.