產(chǎn)品與市場
S1600
特點(diǎn)
● 優(yōu)異的耐漏電起痕性,CTI≥600V● UV Blocking
● 優(yōu)良的PCB加工性
● 不適合翻洗綠油(阻焊油墨)
應(yīng)用領(lǐng)域
● 等離子顯示屏、液晶顯示屏、電源基板、電視機(jī)、電冰箱、洗衣機(jī)等
● 不適用于有CAF要求的應(yīng)用
● 不適用于有CAF要求的應(yīng)用
- 產(chǎn)品性能
- 產(chǎn)品證書
- 資料下載
Items | Method | Condition | Unit | Typical Value | |
---|---|---|---|---|---|
Tg | IPC-TM-650 2.4.25 | DSC | ℃ | 135 | |
Td | IPC-TM-650 2.4.24.6 | 5% wt. loss | ℃ | 310 | |
CTE (Z-axis) | IPC-TM-650 2.4.24 | Before Tg | ppm/℃ | 55 | |
After Tg | ppm/℃ | 308 | |||
50-260℃ | % | 4.5 | |||
Thermal Stress | IPC-TM-650 2.4.24.13 | 288℃, solder dip | -- | >100S No Delamination | |
Volume Resistivity | IPC-TM-650 2.5.17.1 | After moisture resistance | MΩ.cm | 5.0E + 08 | |
E-24/125 | MΩ.cm | 5.0E + 06 | |||
Surface Resistivity | IPC-TM-650 2.5.17.1 | After moisture resistance | MΩ | 5.0E + 07 | |
E-24/125 | MΩ | 5.0E + 06 | |||
Arc Resistance | IPC-TM-650 2.5.1 | D-48/50+D-4/23 | s | 126 | |
Dielectric Breakdown | IPC-TM-650 2.5.6 | D-48/50+D-4/23 | kV | 60 | |
Dissipation Constant (Dk) | IPC-TM-650 2.5.5.9 | 1MHz | -- | 4.7 | |
IEC 61189-2-721 | 10GHz | -- | — | ||
Dissipation Factor (Df) | IPC-TM-650 2.5.5.9 | 1MHz | -- | 0.016 | |
IEC 61189-2-721 | 10GHz | -- | — | ||
Peel Strength (1oz HTE copper foil) | IPC-TM-650 2.4.8 | A | N/mm | — | |
After thermal Stress 288℃,10s | N/mm | 1.8 | |||
125℃ | N/mm | 1.6 | |||
Flexural Strength | LW | IPC-TM-650 2.4.4 | A | MPa | 550 |
CW | IPC-TM-650 2.4.4 | A | MPa | 450 | |
Water Absorption | IPC-TM-650 2.6.2.1 | E-1/105_D-24/23 | % | 0.10 | |
CTI | IEC60112 | A | Rating | PLC 0 | |
Flammability | UL94 | C-48/23/50 | Rating | V-0 | |
E-24/125 | Rating | V-0 |
Remarks:
1. Specification sheet: IPC-4101/21, is for your reference only.
2. All the typical value is based on the 1.6mm specimen,while the Tg is for specimen≥0.50mm.
3. All the typical value listed above is for your reference only,please turn to Shengyi Technology Co., Ltd. for detailed information, and all rights from this data sheet are reserved by Shengyi Technology Co., Ltd.
Explanations: C=Humidity conditioning, D=Immersion conditioning in distilled water, E=Temperature conditioning
The figures following the letter symbols indicate with the first digit the duration of the preconditioning in hours, with the second digit the preconditioning temperature in ℃ and with the third digit the relative humidity.